HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Installation Guide, V4.2.X (AA-RVULB-TE, April 2004)
Installing the SAN Switch
50 SAN Switch 2/8V, 2/16V and 2/16N Installation Guide
4. Open a terminal emulator application (such as HyperTerminal on a PC or
TERM in a UNIX environment) and configure the application as follows:
■ In a Windows 95, 98, 2000, or NT environment:
■ In a UNIX environment, type the following string at the prompt:
tip /dev/ttyb -9600
Power Up the Switch and Log In
Once a serial connection is established, provide power to the switch; power is
supplied to the switch as soon as the first power supply is connected and powered
on:
1. Connect the power cords to both power supplies and power sources
(Figure 15).
Figure 15: Connecting the power cords
Bits per second 9600
Databits 8
Parity None
Stop bits 1
Flow control None
0015a