HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Installation Guide, V4.2.X (AA-RVULB-TE, April 2004)
Installing the SAN Switch
51SAN Switch 2/8V, 2/16V and 2/16N Installation Guide
To protect against AC failure, connect the power cords to outlets on separate
circuits. Ensure that the cords have a minimum service loop of six inches
available at the connection to the switch and are routed to avoid stress.
The power supply LED lights up green, and the switch begins running Power
On Post Test (POST). POST should complete and the switch will complete
the boot process in about three minutes.
2. After POST is complete, verify that the System Status and Power Status LEDs
are green.
3. Using a serial connection, when the terminal emulator application stops
reporting information, press Enter to display the login prompt.
4. Log in using the administrative account; the logon is “admin” and the default
password is “password”. Up to two simultaneous admin sessions and four
user sessions can be created. For details, refer to the
HP StorageWorks Fabric
OS Procedures 4.2x User Guide and the Fabric OS 4.2.x Command Reference
Guide.
Set the IP Address
Replace the default IP address and related information with the information
provided by your network administrator:. By default, the IP address is set to
10.77.77.77.
1. Type ipaddrset at the terminal emulator application prompt.
2. Type the requested information as prompted.
Example:
3. Optionally, verify that the address was correctly set by entering the
ipaddrshow command at the prompt.
4. Record the IP address on the label clearly displayed on the port side of the
chassis.
switch:admin> ipaddrset
Ethernet IP Address [192.168.1.1]:10.32.53.47
Ethernet Subnetmask [255.255.255.0]:255.255.240.0
Fibre Channel IP Address [0.0.0.0]:
Fibre Channel Subnetmask [0.0.0.0]:
Gateway IP Address [0.0.0.0]:10.32.48.1
Set IP address now? [y = set now, n = next reboot]:y
IP address being changed...
Committing configuration...Done.
switch:admin>