HP StorageWorks SAN Switch 2/8V, 2/16V and 2/16N Installation Guide, V4.2.X (AA-RVULB-TE, April 2004)
Installing the SAN Switch
55SAN Switch 2/8V, 2/16V and 2/16N Installation Guide
The cables used in trunking groups must meet specific requirements. For a list of
these requirements, refer to the HP StorageWorks Fabric OS Features 4.2.x User
Guide.
Verifying Configuration
After completing the configuration, use the LEDs and commands to verify that the
configuration has been accepted:
1. Check the LEDs to verify that all components are functional. For information
about LED patterns, refer to “Interpreting LED Activity” on page 59.
2. Verify the correct operation of the SAN Switch 2/8V and SAN Switch 2/16V
by entering the switchshow command from the workstation. This command
provides information about the switch and port status.
3. Verify the correct operation of the SAN Switch 2/8V and SAN Switch 2/16V
in the fabric by entering the fabricshow command from the workstation. This
command provides general information about the fabric.
Backing Up Your Configuration
HP recommends regular backups to ensure that a recent configuration is available
for downloading to a replacement switch, if required. For specific instructions
about how to back up the configuration, refer to the HP StorageWorks Fabric OS
Procedures 4.2x User Guide.
Back up the switch configuration to an FTP server by entering the configupload
command and following the prompts. This command uploads the switch
configuration to the server, making it available for downloading to a replacement
switch, if necessary.