Brocade Fabric Manager Administrator's Guide (53-10000196-01-HP, November 2006)

Fabric Manager Administrator’s Guide 18-9
Publication Number: 53-1000196-01-HP
Monitoring Link Incidents
18
Monitoring Link Incidents
Problems that occur on links between a host and the switch, or between the storage CUP and the switch
are known as link incidents. Any FRU failures are referred to as implicit link incidents. Table 18-1
describes the types of link and implicit link incidents.
To monitor link and implicit link incidents
1. Select a switch from the View panel.
2. Click the Events tab in the Information panel.
3. Check the value in the Source column within the Events tab.
The Source column identifies the source of link incidents as FICON or MSFICON. The source of
implicit link incidents are identified as EM or FW.
Cascaded FICON Setup
This section describes how you can use Fabric Manager to configure a fabric for cascaded FICON and
to merge two fabrics for cascaded FICON.
You can configure a fabric for cascaded FICON only if all switches in the fabric are running
Fabric OS v5.2.0 or higher. You cannot configure a secure fabric for cascaded FICON with the Fabric
Manager FICON Configuration utility.
To merge two fabrics for cascaded FICON, both fabrics must have all switches running Fabric OS
v5.2.0 or higher.
Configure a Fabric for Cascaded FICON
Using Fabric Manager, you can easily configure a fabric for cascaded FICON. You launch the utility,
select a fabric to configure, indicate whether you want FMS mode set, and click OK. Fabric Manager
then performs the following operations on the selected fabric:
Turns on the insistent domain ID flag (IDID) on all switches.
Enables port-based routing on 4 Gbit/sec platform switches.
Disables Dynamic Load Sharing (DLS) on all switches.
Table 18-1 Types of Link and Implicit Link Incidents
Link Incidents Implicit Link Incidents (FRU Failures)
Bit-error-rate threshold exceeded
Loss of signal or synchronization
Non-operational primitive sequence
(NOS) recognized
Primitive sequence time-out
Invalid primitive sequence for port state
WWN card
Power supply
System hardware slot
Fan