Brocade Web Tools Administrator's Guide (53-0000194-01, November 2006)

7-16 Web Tools Administrator’s Guide
Publication Number: 53-0000194-01
7
See “Configuring Interfaces, Routes, and Tunnels” on page 7-9 for additional information on
configuring the tunnels.
To add a new FCIP tunnel
1. Click a port in the Switch View to launch the Port Management module in a separate window (see
Figure 5-1 on page 5-2).
2. Click the GigE Ports tab.
3. Click on the port you want to edit.
4. Click the FCIP Tunnels subtab.
Figure 7-6 FCIP Tunnels Tab for GbE Ports
5. Click New in the task bar.
The GigE Port Configuration wizard launches. The wizard fields are populated with the current
configuration values.
6. Follow the steps outlined in the wizard.
C
aution
Both ends of the tunnel must be identically configured. Compression, fastwrite, tape pipelining, or IKE/
IPSec needs to be either enabled or disabled at both ends of the tunnel. In the case of a mismatch, the
tunnel will not be established.
C
aution
Adding or editing an active route being used by an FCIP tunnel may result in a loss of connection on the
FCIP tunnel and corresponding VE_Port.