HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide (AA-RTQVD-TE, May 2004)
Installing the SAN Switch 2/32
39SAN Switch 2/32 Version 4.2.x Installation Guide
Power On Self-Test
Each time the switch is powered on, rebooted, or reset, it automatically runs
POST. During POST, the port status LEDs flash, verifying that the switch is
operating properly. POST completes in approximately six minutes, with total boot
time approximately seven minutes.
POST runs through the following test cycles:
■ Preliminary POST diagnostics
■ Initialization of operating system
■ Initialization of hardware
■ Diagnostic tests, which are run on a number of functions, including circuitry,
port functionality, memory, parity, statistics counters, and serialization
If the switch prompt does not display when POST completes, POST is
unsuccessful. Contact your authorized HP switch supplier for more information.
To determine whether POST completed without errors, verify that all LEDs return
to a normal state after POST is complete. If one or more LEDs do not return to a
normal state (and this is not due to the switch being set to beacon), see
“Interpreting LED Activity” in Chapter 3.
Note: For more information about beaconing, refer to the
HP StorageWorks Fabric
OS 4.2.x Procedures User Guide
.
Checking POST Results
Check the success/fail results of the diagnostic tests run during POST via LED
activity, the error log, or CLI using the errShow command. For more
information about error messages, refer to the HP StorageWorks
Diagnostic and
System Error Messages 4.2.x Reference Guide.
Configuring SAN Switch 2/32 Network Addressing
This section contains information on how to configure the SAN Switch 2/32
addressing scheme.
For instructions about configuring the switch to operate in a fabric containing
switches from other vendors, refer to the HP StorageWorks Fabric OS 4.2.x
Procedures User Guide.