HP StorageWorks SAN Switch 2/32 V4.2.X Installation Guide (AA-RTQVD-TE, May 2004)

Technical Specifications
73SAN Switch 2/32 Version 4.2.x Installation Guide
.
Environmental Requirements
Table 10 lists the environmental ranges that are acceptable when the switch is
operating, and the acceptable ranges when the switch is not operating.
.
Memory Specifications
The switch utilizes the following memory.
Main Memory (SDRAM): 128 MB per switch
Flash Memory: 32 MB
Boot Flash: 512KB of 8-bit for system boot
Compact Flash: 256 MB
The centralized memory maximizes the overall switch throughput by guaranteeing
full transmit and receive bandwidth to all Fibre Channel ports at all times.
Table 10: Environmental Requirements
Condition Acceptable Range
Temperature (operating) 10×C to 40×C
Temperature (non-operating) -25×C to 70×C
Humidity (operating) 20% to 85% RH non condensing, at
40×C, with maximum gradient with
10% per hour
Humidity (non-operating) 10% to 850% RH non-condensing, at
70°C
Altitude (operating) 0 to 3 km above sea level
Altitude (non-operating) 0 to 12 km above sea level
Shock (operating) 80 G, 2.4 ms, half sine
Shock (non-operating) 20 G, 11 ms, half sine wave