San Switch 2/32 v4.1.x - Installation Guide

Installing the SAN Switch 2/32
66 SAN Switch 2/32 Version 4.1.x Installation Guide
5. Complete the remaining prompts (or press CTRL+D to accept the remaining
settings without completing all the prompts).
6. Re-enable the switch by entering the following:
switchEnable
Specifying Custom Status Policies
Optional If desired, specify any custom status policies for the fabric as follows.
1. Enter the following at the prompt.
switchStatusPolicySet
2. Specify the desired status policies. To completely deactivate the alarm for a
particular condition, enter 0 at the prompt for that condition.
Note: Configure each port to match the topology of each host or target before
connecting to the device. The default port configuration is fabric, not private loop. The
switch does not auto-sense topology.
Connecting the SAN Switch 2/32 to the Fabric
Use these steps to connect the SFPs and cables to SAN Switch 2/32 ports as
required.
Note: The ports and cables used in trunking groups must meet specific requirements.
For a list of these requirements, refer to the
HP StorageWorks ISL Trunking Version
3.1.x/4.1.x User Guide
.
1. Remove the shipping plug from the appropriate ports.
2. Position the SFP so that the key (the tab near the cable-end of the SFP) is on
top.
3. Insert the SFP into the port until it is firmly seated and the latching
mechanism clicks.