Fabric OS Message Reference 53
53-1000437-01
BL-1017
5
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the
Fabric OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1017
Message <timestamp>, [BL-1017], <sequence-number>,, INFO, <system-name>, Slot <slot
number>
Initializing...
Probable Cause Indicates that the slot has started initializing the ports.
Recommended
Action
No action is required.
Severity INFO
BL-1018
Message <timestamp>, [BL-1018], <sequence-number>,, INFO, <system-name>, Slot <slot
number>
Initialization completed.
Probable Cause Indicates that the slot has completed initializing the ports.
Recommended
Action
No action is required.
Severity INFO
BL-1019
Message <timestamp>, [BL-1019], <sequence-number>,, INFO, <system-name>, Slot <Slot
number>, retry <Retry Number>, internal port retry initialization, <List of
internal ports retrying initialization>.
Probable Cause Indicates that the slot had internal ports not online and that the system is retrying to bring the ports
that failed back online.
Recommended
Action
No action is required.
Severity INFO