BL-1023
5
BL-1023
Message <timestamp>, [BL-1023], <sequence-number>,, CRITICAL, <system-name>, Blade in
slot
<slot number> was reset before blade init completed. As a result the blade
is faulted.
Probable Cause Indicates that the blade was reset before the initialization completed.
Recommended
Action
Reboot or power cycle the blade.
If the message persists, replace the blade.
Severity CRITICAL
BL-1024
Message <timestamp>, [BL-1024], <sequence-number>,, INFO, <system-name>, All ports on the
blade in slot
<slot number> will be reset as part of the firmware upgrade.
Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted
in the cold upgrade. As part of the upgrade, all datapath elements were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1025
Message <timestamp>, [BL-1025], <sequence-number>,, INFO, <system-name>, All GigE/FCIP
Virtualization ports on the blade in slot
<slot number> will be reset as part of
the firmware upgrade.
Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted
in the cold upgrade. As part of the upgrade, all GigE/Fibre Channel over IP (FCIP) Virtualization data
elements were reset.
Recommended
Action
No action is required.
Severity INFO
BL-1026
Message <timestamp>, [BL-1026], <sequence-number>,, CRITICAL, <system-name>, Internal
port offline during warm recovery, state <port state> (0x<port ID>).
Probable Cause Indicates that an internal port went offline during the warm recovery of the switch.The switch will
reboot and start a cold recovery.