Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

62 Fabric OS Message Reference
53-1000437-01
BM-1004
7
Recommended
Action
Use the slotPoweroff and slotPoweron commands or reseat the affected blade. On the Brocade
7500 or 7600, switch off and on all primary power in order to power-cycle the unit.
Severity WARNING
BM-1004
Message <timestamp>, [BM-1004], <sequence-number>,, INFO, <system-name>, Blade firmware
<Blade firmware> on slot < Slot > is not consistent with system firmware <System
firmware>. Auto-leveling blade firmware to match system firmware.
Probable Cause The policy of the specified blade is to auto-level the blade firmware to the system firmware.The
inconsistency may be due to either of the following reasons:
Blade firmware was detected to be different from the control processor (CP) firmware due to a
firmware upgrade.
The blade was just inserted and had a different version of the firmware loaded.
Recommended
Action
No action is required. The blade will automatically download the updated firmware.
Severity INFO
BM-1005
Message <timestamp>, [BM-1005], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for blade in slot
<Slot>. Faulting blade.
Probable Cause The firmwareDownload command failed for the blade in the specified slot.
Recommended
Action
Use the slotPoweroff and slotPoweron commands or reseat the affected blade. On the Brocade
7500 or 7600, switch off and on all primary power in order to power-cycle the unit.
Severity WARNING
BM-1006
Message <timestamp>, [BM-1006], <sequence-number>,, INFO, <system-name>, Blade is not
configured. Persistently disabling all ports for blade in slot
<Slot number>.
Probable Cause The policy of the specified blade is set to persistently disable all ports the first time the blade is
detected. The message indicates either of the following:
The blade was detected in this slot for the first time.
The blade was configured under a different mode.
Recommended
Action
Configure the blade so that it will persistently enable the ports.
Severity INFO