Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

64 Fabric OS Message Reference
53-1000437-01
BM-1055
7
Recommended
Action
No action is required. The blade will automatically download the updated firmware.
Severity INFO
BM-1055
Message <timestamp>, [BM-1055], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for AP. Faulting switch.
Probable Cause The firmwareDownload command on the application processor (AP) blade failed.
Recommended
Action
Use the slotPoweroff and slotPoweron commands or reseat the affected blade. On the Brocade
7500 or 7600, switch off and on all primary power in order to power-cycle the unit.
Severity WARNING
BM-1056
Message <timestamp>, [BM-1056], <sequence-number>,, INFO, <system-name>, AP is not
configured. Persistently disabling all ports on the switch.
Probable Cause The policy of the specified switch is to persistently disable all ports the first time the application
processor (AP) blade is detected. This may be cause by one of the following:
The AP was detected for the first time on this switch.
The switch was configured under a different mode.
Recommended
Action
Configure the switch to persistently enable all ports.
Severity INFO
BM-1058
Message <timestamp>, [BM-1058], <sequence-number>,, WARNING, <system-name>, Download of
AP firmware failed for the switch. Reissue firmwaredownload to recover.
Probable Cause The automatic firmware upgrade on the application processor (AP) has failed because the firmware
version running on the AP was detected to be different from system firmware due to a firmware
upgrade.
Recommended
Action
Issue the firmwareDownload command to recover the AP.
Severity WARNING