Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 75
53-1000437-01
EM-1012
11
EM-1012
Message <timestamp>, [EM-1012], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id> failed <state> state transition, FRU faulted.
Probable Cause Indicates that a switch blade or nonbladed switch failed to transition from one state to another. It is
faulted. The specific failed target state is displayed in the message. There are serious internal
Fabric OS configuration or hardware problems on the switch.
Recommended
Action
On Brocade 24000 and 48000, try reseating the indicated field-replaceable unit (FRU).
If the message persists, reboot or power cycle the switch.
Run the systemVerification command to verify that the switch does not have hardware problems.
Refer to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the FRU.
Severity CRITICAL
EM-1013
Message <timestamp>, [EM-1013], <sequence-number>,, ERROR, <system-name>, Failed to
update FRU information for
<FRU Id>.
Probable Cause Indicates that the environmental monitor was unable to update the time alive or the original
equipment manufacturer (OEM) data in the memory on a field-replaceable unit (FRU).
Recommended
Action
If you ran the fruInfoSet command, try the command again; otherwise, the update is automatically
attempted again. If it continues to fail, try reseating the FRU.
If the message persists, replace the FRU.
Severity ERROR
EM-1014
Message <timestamp>, [EM-1014], <sequence-number>,, ERROR, <system-name>, Unable to read
sensor on <FRU Id> (<Return code>)
Probable Cause Indicates that the environmental monitor was unable to access the sensors on the specified
field-replaceable unit (FRU).
Recommended
Action
Try reseating the FRU. If the message persists, replace the FRU.
Severity ERROR