Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

140 Fabric OS Message Reference
53-1000437-01
FICU-1004
21
Severity WARNING
FICU-1004
Message <timestamp>, [FICU-1004], <sequence-number>,, WARNING, <system-name>, <function
name>: Failed to set fabric manager server (FMS) mode: conflicting PID
Format:<pid_format>, FMS Mode:<mode>.
Probable Cause Indicates that a process ID (PID) format conflict was encountered. The core PID format is required
for fibre connectivity control unit port (FICON-CUP).
The pid_format variable displays the PID format currently running on the fabric, and is one of the
following:
0 is VC-encoded PID format
1 is core PID format
2 is extended-edge PID format
FMS mode displays whether fibre connectivity (FICON) Management Server mode is enabled; a 0
means this mode is enabled and a 1 means this mode is disabled.
Recommended
Action
For FICON Management Server mode (fmsMode) to be enabled, the core PID format must be used
in the fabric. Change the PID format to core PID using the configure command and reenable
fmsmode using the ficonCupSet command. Refer to the Fabric OS Administrator’s Guide for
information on core PID mode and the Fabric OS Command Reference for information on the
configure command and ficonCupSet command.
Severity WARNING
FICU-1005
Message <timestamp>, [FICU-1005], <sequence-number>,, ERROR, <system-name>, Failed to
initialize <module>, rc = <error>.
Probable Cause Indicates that the initialization of a module within the fibre connectivity control unit port
(FICON-CUP) daemon failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference for more information on this command.
Severity ERROR
FICU-1006
Message <timestamp>, [FICU-1006], <sequence-number>,, WARNING, <system-name>, Control
Device Allegiance Reset (Logical Path: 0x<PID>:0x<channel image ID>)
Probable Cause Indicates that the path with the specified PID and channel image ID lost allegiance to a fibre
connectivity control unit port (FICON-CUP) device.