Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 151
53-1000437-01
FSS-1006
25
FSS-1006
Message <timestamp>, [FSS-1006], <sequence-number>,, WARNING, <system-name>, No FSS
message available
Probable Cause Indicates that data is not available on the Fabric OS state synchronization (FSS) device.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
FSS-1007
Message <timestamp>, [FSS-1007], <sequence-number>,, CRITICAL, <system-name>,
<component name>: Faulty Ethernet connection.
Probable Cause Indicates that the Ethernet connection between the active control processor (CP) and standby CP is
not healthy. The error occurs when the standby CP does not respond to a request from the active
CP within 5 seconds. This usually indicates a problem with the internal Ethernet connection and a
disruption of the synchronization process.
Recommended
Action
Check the Ethernet connection between active CP and standby CP (interface eth1) by issuing net
commands such as ifconfig eth1 (as root) or run supportShow/supportSave to validate the network
configuration; then try to restore the synchronization by issuing the haSyncStart command. If the
problem persists, contact your switch service provider.
Severity CRITICAL