Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

252 Fabric OS Message Reference
53-1000437-01
HIL-1508
30
HIL-1508
Message <timestamp>, [HIL-1508], <sequence-number>, FFDC, CRITICAL, <system-name>, Fan
faulty warning time expired. System preparing for shutdown.
Probable Cause Indicates that temperatures in the system have remained above the critical threshold too long.
Recommended
Action
In order to avoid causing damage to the switch, the system shuts down automatically. To help
prevent future problems, make sure that all the fans are working properly.
Make sure that the area is well ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity CRITICAL
HIL-1509
Message <timestamp>, [HIL-1509], <sequence-number>, FFDC, CRITICAL, <system-name>, High
temperature (
<measured temperature> C). Warning time expired. System preparing
for shutdown.
Probable Cause Indicates that temperatures in the system have risen above the critical threshold.
Recommended
Action
In order to avoid causing damage to the switch, the system shuts down automatically. To help
prevent future problems, make sure that all the fans are working properly.
Make sure that the area is well ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity CRITICAL
HIL-1510
Message <timestamp>, [HIL-1510], <sequence-number>,, WARNING, <system-name>, Current
temperature (
<measured temperature> C) is below shutdown threshold. System
shutdown cancelled.
Probable Cause Indicates that temperatures in the system have dropped below the critical threshold, so that the
system can continue operation.
Recommended
Action
To help prevent future problems, make sure that all the fans are working properly.
Make sure that the area is well ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.
Severity WARNING