Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

304 Fabric OS Message Reference
53-1000437-01
PDM-1004
51
PDM-1004
Message <timestamp>, [PDM-1004], <sequence-number>,, WARNING, <system-name>, PDM memory
shortage.
Probable Cause Indicates that the parity data manager (PDM) process ran out of memory.
Recommended
Action
Reboot or power cycle the switch.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1005
Message <timestamp>, [PDM-1005], <sequence-number>,, WARNING, <system-name>, FSS register
failed.
Probable Cause Indicates that the parity data manager (PDM) failed to register with the Fabos synchronization
service (FSS).
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1006
Message <timestamp>, [PDM-1006], <sequence-number>,, WARNING, <system-name>, Too many
files in sync.conf.
Probable Cause Indicates that the configuration file sync.conf contains too many entries.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1007
Message <timestamp>, [PDM-1007], <sequence-number>,, WARNING, <system-name>, File not
created:
<file name>.
Probable Cause Indicates that the parity data manager (PDM) process failed to create the specified file.