Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 321
53-1000437-01
Chapter
57
RAS System Messages
RAS-1001
Message <timestamp>, [RAS-1001], <sequence-number>,, INFO, <system-name>, First failure
data capture (FFDC) event occurred.
Probable Cause Indicates that a failure happened and the failure data was captured.
Recommended
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave
command and contact your switch service provider.
Severity INFO
RAS-1002
Message <timestamp>, [RAS-1002], <sequence-number>,, WARNING, <system-name>, First
failure data capture (FFDC) maximum storage size (
<log size limit> MB) was
reached.
Probable Cause Indicates that the maximum storage size for FFDC data capture is reached.
Recommended
Action
Run the supportSave command and contact your switch service provider.
Severity WARNING
RAS-1003
Message <timestamp>, [RAS-1003], <sequence-number>,, WARNING, <system-name>, Audit
message log is
<____message____>.
Probable Cause Indicates the current state of the audit message log.
Recommended
Action
No action is required.