Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 361
53-1000437-01
SEC-1105
63
SEC-1105
Message <timestamp>, [SEC-1105], <sequence-number>,, ERROR, <system-name>, Fail to
disable secure mode on all switches.
Probable Cause Indicates that the switch failed to disable security in the fabric. This could happen if the switch
cannot get the required resources to complete the command, and sending to a remote domain
fails or the remote domain returns an error.
Recommended
Action
Run the secFabricShow to verify that all switches in the fabric are in the ready state. Retry the
command when all switches are READY.
Severity ERROR
SEC-1106
Message <timestamp>, [SEC-1106], <sequence-number>,, ERROR, <system-name>, Failed to sign
message data.
Probable Cause Indicates that some public key infrastructure (PKI) objects on the switch are not in a valid state,
and a signature operation failed.
Recommended
Action
Run the pkiShow command and verify that all PKI objects exist on the switch. If a failure to validate
PKI objects occurs, follow the steps for re-creating PKI objects outlined in the Secure Fabric OS
Administrator's Guide.
Severity ERROR
SEC-1107
Message <timestamp>, [SEC-1107], <sequence-number>,, INFO, <system-name>, Stamp is 0.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity INFO