Message <timestamp>, [SEC-1112], <sequence-number>,, ERROR, <system-name>, FCS list must
be the first entry in the Active Security policies, and the same as the current
active FCS list in the switch.
Probable Cause Indicates that either a security policy download is attempted with an active policy that does not
have the fabric configurations server (FCS) policy as the first policy or the FCS policy is not same as
the current FCS policy on the switch.
Recommended
Action
Make sure that the new FCS policy is the same as the current FCS policy on the switch.
Severity ERROR
SEC-1115
Message <timestamp>, [SEC-1115], <sequence-number>,, ERROR, <system-name>, No primary FCS
to failover.
Probable Cause Indicates that during an attempted secFcsFailover, no primary fabric configurations server (FCS) is
present in the fabric.
Recommended
Action
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When
all switches are in the ready state, retry the operation.
Severity ERROR
SEC-1116
Message <timestamp>, [SEC-1116], <sequence-number>,, ERROR, <system-name>, Fail to commit
failover.
Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can
only occur when the primary fabric configurations server (FCS) is distributing the security database
to the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR