Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

364 Fabric OS Message Reference
53-1000437-01
SEC-1117
63
SEC-1117
Message <timestamp>, [SEC-1117], <sequence-number>,, INFO, <system-name>, Fail to set
<data>.
Probable Cause Indicates that the switch failed to save the data received by the primary fabric configurations
server (FCS) switch. This data can be an FCS password, a non-FCS password, SNMP data, or
multiple user authentication data.
Recommended
Action
Run the secFabricShow command to verify that all switches in fabric are in the ready state. When
all switches are in the ready state, retry the operation.
Severity INFO
SEC-1118
Message <timestamp>, [SEC-1118], <sequence-number>,, INFO, <system-name>, Fail to set
SNMP string.
Probable Cause Indicates that the SNMP string could not be set.
Recommended
Action
Usually this problem is transient. Retry the command.
Severity INFO
SEC-1119
Message <timestamp>, [SEC-1119], <sequence-number>,, INFO, <system-name>, Secure mode has
been enabled.
Probable Cause Indicates that the secure Fabric OS was enabled by the secModeEnable command.
Recommended
Action
Verify that the security event was planned. If the security event was planned, there is no action
required. If the security event was not planned, take appropriate action as defined by your
enterprise security policy.
Severity INFO