Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

396 Fabric OS Message Reference
53-1000437-01
SNMP-1004
64
SNMP-1004
Message <timestamp>, [SNMP-1004], <sequence-number>, FFDC, ERROR, <system-name>,
Incorrect SNMP configuration.
Probable Cause Indicates that the simple network management protocol (SNMP) configuration is incorrect and the
SNMP service will not work correctly.
Recommended
Action
Change the SNMP configuration back to the default.
Severity ERROR
SNMP-1005
Message <timestamp>, [SNMP-1005], <sequence-number>, AUDIT, INFO, <system-name>, SNMP
configuration attribute, <Changed attribute>, has changed from <Old Value> to <New
Value>
Probable Cause Indicates that the simple network management protocol (SNMP) configuration has changed. The
parameter that was modified is displayed as well as the old and new values for that parameter.
Recommended
Action
Execute the snmpConfig --show command to see the new configuration.
Severity INFO
SNMP-1006
Message <timestamp>, [SNMP-1006], <sequence-number>, AUDIT, INFO, <system-name>, <SNMP
Configuration group>
configuration was reset to default
Probable Cause Indicates that the simple network management protocol (SNMP) configuration group was reset to
the factory default.
Recommended
Action
Execute the snmpConfig --show for the group to see the new configuration.
Severity INFO