Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 417
53-1000437-01
Chapter
68
SYSC System Messages
SYSC-1001
Message <timestamp>, [SYSC-1001], <sequence-number>, FFDC, CRITICAL, <system-name>,
Failed to run <Name of program that could not be run (string)>:<System internal
error message (string)>.
Probable Cause Indicates that during the boot sequence, one of the programs would not run on the system.
Recommended
Action
If the message is reported during a reboot after new firmware has been loaded, try reloading the
firmware using the firmwareDownload command.
If the message persists, there might be a conflict between the two versions of firmware or the
nonvolatile storage might be corrupted. Run supportFtp (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity CRITICAL
SYSC-1002
Message <timestamp>, [SYSC-1002], <sequence-number>, FFDC, CRITICAL, <system-name>,
Switch bring-up timed out.
Probable Cause Indicates that the system timed out during a reboot or failover sequence, waiting for one or more
programs to register with system services or to fail over to active status.
Recommended
Action
The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before
rebooting the chassis, record the firmware version on the switch or control processor (CP) and run
the haDump command. If this is a dual-CP switch, then gather the output from the CP in which this
log message appeared.
Severity CRITICAL