Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 25
53-1000437-01
Chapter
2
AG System Messages
AG-1001
Message <timestamp>, [AG-1001], <sequence-number>,, ERROR, <system-name>, N_Port ID
virtualization (NPIV) is not supported by fabric port connected to port <port>.
Probable Cause N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which the Access
Gateway is connected.
Recommended
Action
On Brocade, Fabric OS based switches execute the portCfgNpivPort command on the fabric
switch to enable NPIV capability on the port connected to the Access Gateway. Refer to the
Fabric OS Command Reference manual for more information on this command.
Some blades within a switch or some ports within a switch or blade may not have support for
NPIV capability. NPIV functionality cannot be enabled on such ports and they will not respond
to NPIV requests. refer to the Access Gateway Administrator Guide, Appendix B for specific AG
compatibility requirements.
On non-Brocade switches, refer to the manufacture's documentation to determine whether the
switch supports NPIV and how to enable NPIV on these types of switches.
Severity ERROR
AG-1002
Message <timestamp>, [AG-1002], <sequence-number>,, WARNING, <system-name>, Unable to
find alternate N_Port during failover for N_Port
<port>.
Probable Cause No other N_Port is configured or the fabric was unstable during failover.
Recommended
Action
Please check whether or not an alternate N_Port is configured.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
AG-1003
Message <timestamp>, [AG-1003], <sequence-number>,, WARNING, <system-name>, Unable to
failover N_Port <port>. Failover across different fabrics is not supported.
Probable Cause Failover across N_Ports connected to different fabrics is not supported.
Recommended
Action
Please configure two or more N_Ports to connect to the same fabric; then execute ag
--failoverEnable to enable failover on these N_Ports.