Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

Fabric OS Message Reference 47
53-1000437-01
Chapter
5
BL System Messages
BL-1000
Message <timestamp>, [BL-1000], <sequence-number>,, INFO, <system-name>, Initializing
ports...
Probable Cause Indicates that the switch has started initializing the ports.
Recommended
Action
No action is required.
Severity INFO
BL-1001
Message <timestamp>, [BL-1001], <sequence-number>,, INFO, <system-name>, Port
initialization completed.
Probable Cause Indicates that the switch has completed initializing the ports.
Recommended
Action
No action is required.
Severity INFO
BL-1002
Message <timestamp>, [BL-1002], <sequence-number>, FFDC, CRITICAL, <system-name>, Init
Failed: slot <slot number> DISABLED because internal ports were not ONLINE, <list
of internal port number not ONLINE>.
Probable Cause Indicates that the blade initiation failed because one or more of the internal ports were not online.
The blade is faulted.
Recommended
Action
Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle
the blade.
Run the systemVerification command to verify that the blade does not have hardware problems.
Note that any reference seen to slot 0 is a reference to the blade within the switch platform,
e.g.,Brocade 7500 and AP7600 contain FR4-18i and FA4-18 blades respectively.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the
Fabric OS Command Reference for more information on these command.