50 Fabric OS Message Reference
53-1000437-01
BL-1010
5
Probable Cause Indicates that the blade has failed to initialize the application-specific integrated circuit (ASIC)
chips.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the
Fabric OS Command Reference for more information on these commands.
If the message persists, replace the blade.
Severity CRITICAL
BL-1010
Message <timestamp>, [BL-1010], <sequence-number>,, WARNING, <system-name>, Blade in slot
<slot number> inconsistent with the hardware settings.
Probable Cause Indicates that a failover occurred while some hardware changes were being made on the
previously active control processor (CP) (such as changing the domain ID).
Recommended
Action
No action is required. This blade has been reinitialized. Because reinitializing a blade is a
disruptive operation and can stop I/O traffic, you might have to stop and restart the traffic during
this process.
Severity WARNING
BL-1011
Message <timestamp>, [BL-1011], <sequence-number>, FFDC, CRITICAL, <system-name>, Busy
with emb-port int. for chip <chip number> in minis <minis number> on blade <slot
number>, chip int. is disabled. interrupt status=0x<interrupt status>.
Probable Cause Indicates that too many interrupts in the embedded port caused the specified chip to be disabled.
The probable cause is too many abnormal frames; the chip is disabled to prevent the control
processor (CP) from becoming too busy.
Recommended
Action
Make sure to capture the console output during this process.
Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port.
Run the systemVerification command to verify that the blade or switch does not have hardware
problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.
On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot or power cycle the switch.
If the message persists, replace the blade or the nonbladed switch.
Severity CRITICAL