HP StorageWorks Fabric OS 5.3.1b release notes (5697-7644, August 2008)

Closed defect summary
Solution
Web Tools event ltering uses a time range of 0-11 rather than 1 -12.
In Web Tools Fab
ric Events and Events window, on invoking lter
button and ltering based on “from time or “to time, on providing a
time greater than 12 (e.g. 12:30 PM) will result in an error stating
that time shou
ld be in range of 0-11.
Fixed in Fabri
c OS 5.3.0
Additional Por t Info column in FC Ports tab in Web Tools shows
"None (FMS Mode)" instead of "Disabled (FMS Mode)."
Fixed in Fabric OS 5.3.0
FR4-18i blades rebooted during rmware commit process per
firmwaredownloadstatus output. Process does recover .
Fixed in Fabric OS 5.3.0
With EZSwitc
hSetup, xed zone can’t be congured with all
ports design
ated as storage or hosts. This is correct behavior,
but the mess
age displayed does not describe how to correct the
misconguration should the user attempt to congure in that manner.
Fixed in Fabric OS 5.3.0
Error messages occur during IPsec FCIP IO. Fixed in Fabric OS 5.3.0
Incorrect information returned during Request Nod e Identication
Data (RNID) registration.
Fixed in Fabric OS 5.3.0
User sees w
rong port type after port swap on issuing fwsamshow
from CLI, due to port type getting swapped in the SAM Report.
Fixed in Fabric OS 5.3.0
Due to current h andling of invalid zone type during zone enforcement
after failover, Name Server daemon (nsd) panic results in CP fault
after firmwaredownload.
Fixed in Fabric OS 5.3.0
Unable to view policy details in the absence of IPSEC license from
ShowIPSecuritypolicies.
Fixed in Fabric OS 5.3.0
After cha
nging an expired password and selecting another Admin
Domain d
uring the same session, the password expiration message
and pass
word prompt are displayed again. Currently have to exit
session and re-login after changing an expired password to avoid
this issue.
Fixed in
Fabric OS 5.3.0
Error messages from ACL conguration through SMI are too generic
and don’t contain sufcient information to debug the problem.
Fixed in Fabric OS 5.3.0
Portstats: Selecting the “Show delta” radio button and clicking on
the clear counter button, does not clear the counters. It changes the
values to negative. Clicking the clear counter button again will reset
counter to zero.
Fixed in Fabric OS 5.3.0
May s
ee FFDC warning messages when manually changing switch IP
addr
ess in DHCP network.
Fixed in Fabric OS 5.3.0
Able to establish API session to Admin Domain 255 using user
login which has Admin Domain membership only to Admin Domain
0,whichisnotallowedfromCLI,resultinginerror.UsersofSMIand
Web Tools won’t observe error because all operations performed
via Admin role user.
Fixed in Fabric OS 5.3.0
Web Tools currently not consistent with CLI on
nl
conguring long distance for ports if current Admin Domain owns
them but not switchmembership.
nl
Port long distance settings are read-only for owned ports on
non-owned switches in Web Tools Extended Fabric tab, but e ditable
for owned ports in Web Tools port conguration wizard.
Fixed in Fabric OS 5.3.0
SNMPtrapsrepeatedlysentfromtheswitchevery2secondswhen
port taken out of a fault state implicitly by removing cable or m odule.
Caused by too many port ofine SCNs being sent out during port
fault and recover when there is laser fault.
Fixed in Fabric OS 5.3.0
18