Closed d efect summary
Solution
Firmware downgr
ade to Fabric OS 5.1 or earlier is blocked even
after ports 256 384 are removed from DCC policy created using
[*] option. Currently have to delete DCC policy to avoid this.
Fixed in Fabric OS 5.3.0
Admin user account with permissions to only Admin Domain 255
can create Admin Domains, but only Admin user accounts with
permissions for all Admin Domains s hould be able to d o this.
Fixed in Fabric OS 5.3.0
Conrmation dialog does not appear when name server table closed
by clicking the “X” button. User experiences unexpected close when
clicking X” button.
Fixed in Fabric OS 5.3.0
Detailed vie
w of any device does not refresh properly when Auto
refresh opt
ion is selected & user resizes/scrolls the window.
Fixed in Fabric OS 5.3.0
Role name, and sometimes user name, m issing from error message
when user exits from a Telnet session.
Fixed in Fabric OS 5.3.0
The 2/16v switch produces ARB(vc) ll words instead of idles which
could cause failures with certain long distance devices when running
Fabric OS 5.2 with the following port conguration:
nl
portcfglongdistance <port> LS 1 50
nl
portcfgislmode <port> 1
Fixed in Fabric OS 5.3.0
Web Tools not correctly reecting physical switch state of a
persistently disabled switch when the switch is fastbooted. LEDs are
shown unlit instead of slowly blinking yellow.
Fixed in Fabric OS 5.3.0
No event is generated when the IP address of a switch is changed,
so user can’t determine IP address of the switch was changed by
issuing the command errdump or errshow because IP address
changeeventwasnotregistered.
Fixed in Fabric OS 5.3.0
Several
issues observed in ZoneAdmin and in Admin Domain when
switch
is congur ed in PID format 2, including being unable to see
ports 1
6-32.
Fixed i
n Fabric OS 5.3.0
During stress testing, a signicant delay in trafccomingback
from a Fibre Channel Router (FCR) failure in fully redundant SAN
conguration was seen, as trafc temporarily stopped before taking
redundant path after rebooting one of the FCRs in dual back bone
fabric.
Fixed in Fabric OS 5.3.0
During stress testing, switch may report fabric busy following issuance
of a long string of operations repeatedly.
Fixed in Fabric OS 5.3.0
When using interactive m ode to execute pathinfo,butwithan
invalid source port value, there is no error message.
Fixe
d in Fabric OS 5.3.0
AfterreceivingloginrejectonFC4-16IP, subsequent login attempts
may fail intermittently under some conditions. This can be avoided
by moving the session back to ini t state after rejecting a login.
Fixed in Fabric OS 5.3.0
During stress testing, FC4-16IP may run out of memory if continually
running slotpoweroff/on on multiple FC4-16IP blades for long
period.
Fixed in Fabric OS 5.3.0
In Secure FOS, Web To ols gets null pointer from Java console rather
th
an the modify dialog to modify description and/or status when
trying to modif y default admin and user accounts.
Fixed in Fabric OS 5.3.0 which now
includes all Secure FOS functionality.
Collecting supportsave info on 4/256 could cause error message
on active CP console log.
Fixed in Fabric OS 5.3.0
HP StorageWorks Fabric OS 5.3.1b release notes