HP StorageWorks Fabric OS 5.3.1b release notes (5697-7644, August 2008)
Fabric OS 5.3.1 fixes
Table 8 lists defects closed in the Fabric OS 5.3.1 firmware release.
Table 8 Fabri
cOS5.3.1closeddefects
Closed defect summary
Solution
Management Server Daemon (MSD) panic occurs on switch during
fabric initi
alization. When fabric hasn’t initialized its database during
fabric initialization, MSD gets ipaddress of switches in fabric which
couldleadtomemorycorruptionandcauseMSDtopanic.
Fixed in Fabric OS 5.3.1
Backbone to edge traffic across FCIP links and ISLs may not be
evenly distributed across all possible routes (edge to backbone and
backbone to edge).
Fixed in Fabric OS 5.3.1
WhendisablinganNPIVswitchwhichhasanAccessGateway
connected to it, the F_Ports that failover to the other NPIV switch show
as “No device found” when running nszonemember for these
F_Ports.
Fixed in Fabric OS 5.3.1
When per
fMonitorShow –class ISL 0 command is run,
some swi
tches give incorrect output as follows: The number of
destina
tion domains monitored is set to zero.
Fixed in
Fabric OS 5.3.1
Unexpected switch reboot may occur during hafailover.During
an upgrade, rcsd may get into an infinite loop and block RCS from
completing a sync d ump, leaving RCS transaction hanging. Switch
panic may occur and traffic may be interrupted.
Fixed in Fabric OS 5.3.1
Flooding of an unknown inter-switch F DMI command from
non-Brocade switch causes daemon to be killed due to out of memory
condition, causing the switch to crash.
Fixed in Fabric OS 5.3.1
Linux kernel issue m ay occur on 2Gb switches running Fabric OS
5.3.0x caused by service daemon thread (fwd, nsd, fabricd)
becoming unresponsive due to deadlock condition. This can trigger
a panic, or snmpd hang.
Fixe
d in Fabric OS 5.3.1
Fabric OS crash occasionally seen when Access Gateway enabled
switch is rebooted with large number of Access G ateway devices in
the fabric.
Fixed in Fabric OS 5.3.1
During fastwrite,specific third party device drops a frame that is
not 8 byte aligned.
Fixed in Fabric OS 5.3.1
Wi
th 2Gb switches, hafailover under heavy load across ISLs,
f
ollowed by portdisable/portenable ofE-portscausesport
b
lade fault with tx parity error (error 21).
F
ixed in Fabric OS 5.3.1
When PID-2 change occurs, Web Tools incorrectly translates the PID
format in the NameServer and displays an incorrect account of the
area/ports contained in a zone or alias member list. This can also
happen when attempting to add to a zone or alias list, causing an
incorrect physical port to be added.
Fixed in Fabric OS 5.3.1
During stress test w ith 2Gb switch, when receiv e buffer overflow
occurs, third party device port is stuck in offline state for more than
30 seconds. Portdisable/portenable will recover the port.
Fixed in Fabric OS 5.3.1
Intermittent supportsave failure messages seen during
supportsave loop.
Fixed in Fabric OS 5.3.1
Traffic stops during FCIP testing with tape pipelining enabled, when
host floods the switch with Name Server query. This occurs because
the query response is not passed back to the host on the backbone
switch through the FCR router .
Fixed in Fabric OS 5.3.1
HP StorageWorks Fabric OS 5.3.1b release notes
25