HP StorageWorks Fabric OS 5.3.0c Release Notes (AA-RWEYG-TE, November 2007)

Provides ability to clear 400 MP Router or B -Series MP Router Blade GE por t Error counters using
portStatsClear CLI command.
Fabric OS 5.3.0 xes
Table 3 lists defects closed in the Fabric OS 5.3.0 rmware release.
Table 3 Fabric O
S5.3.0closeddefects
Closed defect summar y
Solution
4/256 Director
running FICON with fsmode enabled & DLS on and
port based route policy panics after upgra de from Fabric OS 5.0.x to
5.1.x or 5.2.0.
Fixed per Fabr
ic OS 5.3.0
Kernel Ops error when counter is overrun during stress to fail test.
Fixed per Fabric OS 5.3.0
Exception error on 4/256 can occur when performing port mirroring
causing reboot.
Fixed per Fabric OS 5.3.0
Tstimezone command doesn’t show correct time and date if
configdownload interface is used to update timezone.
Fixed per Fabric OS 5.3.0
After executing trunk disable/enable on all edge switches in l arge
scalability fabric, a 2/128 E_port became stuck in Loopback mo de.
Fixed per Fabric OS 5.3.0
Admin Domains enforcement on SID/DID not performed.
Portmirror allowed addition of mirror port in Admin Domain3
when SID and DID were not port members.
Fixed per Fabric OS 5.3.0
New active C
P got Oops and reboot during initialization after
hafailover
command issued.
Fixed per Fabric OS 5.3.0
After CP reboot, VE tunnel doesn’t come up due to GE0 port on
FR4-18i stuck in No_Sync state when using copper SFP’s.
Fixed per Fabric OS 5.3.0
Switch doesn’t generate RSCN following zoning changes using
cfgEnable in interop mode, resulting in no PLOGI from hosts, and
no target discovery.
Fixed per Fabric OS 5.3.0
When more than the supported number of Ex_Ports attached to same
edge fabric with FCR switches, switch may panic causing continuous
rebooting.
Fixed per Fabric OS 5.3.0
When more than the supported number of intelligent b l ades (FR4-18i,
FC4-16IP, etc) conguredin4/256,poweringupthe4thand5th
blades at the same time results in a failover.
Fixed per Fabric OS 5.3.0
In rare occurrence, FR4-18i Blade could become faulty after rmware
download and slotpoweron followed by slotpoweroff.
Fixed per Fabric OS 5.3.0
Tape backup job failures occasionally observed in congested IO
conditions due to tape pipelining not properly handling target
recovery.
Fixed per Fabric OS 5.3.0
After changing FID & enabling FCR switch, all connected/active
ports remain disabled.
Fixed per Fabric OS 5.3.0
If active CP fails over after FC4-16ip port Blade runs slotpower on,
all the FC4-16ip iSCSI ports can get stuck at No_Sync” while FC
ports come online.
Fixed per Fabric OS 5.3.0
After an all switches disable on 4/256 with FC4-48 port blades,
standby CP asserted and rebooted.
Fixed per Fabric OS 5.3.0
HAfailover during FC IP IO through IPSec enabled tunnel
sometimes causes VE port to go down, then come back up.
Fixed per Fabric OS 5.3.0
HP StorageWorks Fabric OS 5.3.0c release notes
17