HP StorageWorks Fabric OS 5.3.0c Release Notes (AA-RWEYG-TE, November 2007)

User was able to congure isns client via isnsccfg to communicate
with isns server through a port on FR4-18i, but this will not work (nor
should it).
Fixed per Fabric OS 5.3.0
FICON traps sen
t with wrong “Enterprise” value resulting in trap
being process
ed as a swFault.
Fixed per Fabric OS 5.3.0
In Web Tools customized port detail report, the report will b e
generated for all ports even if the user gives a particula r p ort range
as a lter.
Fixed per Fabric OS 5.3.0
On 2Gb/s platforms, switch panic can occur if unstable or faulty port
generates excessive number of interrupts.
Fixed per Fabric OS 5.3.0
When rebooti
ngtheactiveCPfromRoot,thewarningtextthatis
displayed when rebooting from Admin to warn that rebooting the
active CP wi
ll disrupt trafc, is not displayed.
Fixed per Fabric OS 5.3.0
In edge to backbone fabric conguration with target in backbone
fabric and host in edge fabric, 400 MP Router neither accepted or
aborted a PLOGI. Only happens when there are devices in the fabric
for which the link is taken online/ofine quickly within a short period
of time.
Fixed per Fabric OS 5.3.0
4/64 SAN switch with 5.1.0d experienced HW/SW interlock that
became stuck requiring port disable/enable to clear the condition.
This issue was not reproducible.
Fixed per Fabric OS 5.3.0
Using API
to access default zoning information could cause switch
to panic
due to invalid pointer.
Fixed per Fabric OS 5.3.0
With large zoneset (over 1200 zones) API library crashes as the zone
library does memcpy that doesn’t have terminating zero in the buffer.
Fixed per Fabric OS 5.3.0
Change made i n 5.2.0 to limit the number of FDISCs per unit of time,
caused timeouts of NPIV logins in some BladeServer congurations
with VC-FC.
Fixed per Fabric OS 5.3.0.
When FO
S version prior to 5.2.0 is upgraded to a later version and
the fabric.ops.mode.pidFormat value was previously set to zero, the
switch will continually reboot.
Fixed per Fabric OS 5.3.0
In extremely rare conditions when a particular tim ing window is hit
at the same time an internal end to end monitor wraps its counter,
the standby CP can g et stuck in a reboot loop. The condition is
that due to a race condition, a partial HA update arrives before a
full update from the active CP, resulting in standby CP going into
continuous restart cycle.
Fixed per Fabric OS 5.3.0
When MS request issued with WWN that didn’t exist in the fabric,
the MS Daemon panicked.
Fixed per Fabric OS 5.3.0
The 2/128 was forwarding PLOGI frames received with DID as
br
oadcast format which was causing issues with other devices in
the fabric.
Fi
xed in Fabric OS 5.3.0. No longer
forwards these type of frames.
For platforms running 5.2.0 and above with domain, port zoning,
there is a small window during which if a device sends it PLOGI
very fast, and before the nameserver information has been fully
prop a g ated, the PLOGI may be dropped.
Fixed per Fabric OS 5.3.0
CLI systemverification command incorrectly reports false
positive failure on FC4-16IP Blade. This diagnostic command is not
typically run by a customer.
Fixed per Fabric OS 5.3.0
“Stats menu option doesn’t work when executing minicycle
command.
Fixed per Fabric OS 5.3.0
18