HP StorageWorks Fabric OS 5.3.0c Release Notes (AA-RWEYG-TE, November 2007)

Process login drop due to devices in different edge fabrics with same
node WWN. Applies to 4/256 with FCR-18i Blade, and 400 MP
Router. Routers may not forward the Nameserver request to proper
domain, resulting in request timeout & retries every 2 seconds.
Fixed per Fabric OS 5.3.0
In a FICON environment a Switch panic (in the Management Server
daemon) could
be seen if the switch receives one of three FICON
specicfram
es (FICON GCA P, RLIR, RNID) and the fabric goes
"unstable" ( fabric being rebuilt such as when one of the switches in
the fabric is
powered off) before a response is sent.
Fixed per Fabric OS 5.3.0
Trafc can’t be routed into backbone fabric from EX_Port on 400 MP
RouterwithdomainID7or12andfromFR4-18iBladein4/256
with various domain I D’s.
Fixed per Fabric OS 5.3.0
Rapidly issuing repeated supportsave commands can cause
switch panic due to out of memory condition.
Fixed per Fabric OS 5.3.0
Wheninteropmodesetto1,“DisableNodeNameZoneChecking
paramete
ralsochangesfrom0to1,butreturnsto0afterswitch
reboot .
Fixed per Fabric OS 5.3.0
Due to race condition in RNID command from FICON channels,
FICON CUP daemon crashes and switch panics after switch comes
up then it star ts processing the RNID command. Problem affects
FICON environment for Fabric OS 5.1 and later.
Fixed per Fabric OS 5.3.0
Web Tools error message provided when fmsmode setting fails is
not clear.
Fixed per Fabric OS 5.3.0
Web Too
ls is missing “Invalid CRCS” under Fabric Watch end to end
class p
ull down menu, due to missing “CRC Error” option.
Fixed per Fabric OS 5.3.0
GUI component size squeezed due to lack of proper refresh after
resizing.
Fixed per Fabric OS 5.3.0
Errlog (raslog) messages not available for diagnosing DHCP
problems.
Fixed per Fabric OS 5.3.0
Web Tools allows (switch,port) members to be added as member of a
zone in interop mode, but this won’t actually be created successfully.
Fixed in Fabric OS 5.3.0 by blocking
addit
ion of D,P members & D,P
zoni
ng when in interop mode.
Some switches are segmented with reason alias ID overlap when
selected switches in fabric congured to use Alias Server due to lack
of Alias Server support in Fabric OS 5.2.0.
Fixed per Fabric OS 5.3.0
On Solaris, when switch already in marginal state and another
marginal event occurs, Events list in Call Home ema il not getting
updated with exact reason for the alert.
Fixed per Fabric OS 5.3.0
FCIP error message not correct while editing/adding the subnet mask
of
an IP address that conicts with the existing IP addresses.
Fi
xed per Fabric OS 5.3.0
EZManager doesn’t differentiate ports as storage and hosts if no
devices/hosts connections made.
Fixed per Fabric OS 5.3.0
During stress testing with large number of sent error frames leading to
generation of very big core le,andwatchdogtimertimeout.
Fixed per Fabric OS 5.3.0
E
nc out counter increases on unused ports on 2Gb platforms after
H
Areboot or rmware download.
Fixed per Fabric OS 5.3.0
Web Tools is not displaying “logged in” Radius account information.
Fixed per Fabric OS 5.3.0
Units for temperature, Rx and Tx power are not shown on SFP tab
in Web Tools.
Fixed per Fabric OS 5.3.0
W
eb Tools doesn’t display units of Total B andwidth and Bandwidth
Demand in Fabric Topology Window.
Fixed per Fabric OS 5.3.0
HP StorageWorks Fabric OS 5.3.0c release notes
19