HP StorageWorks Fabric OS 5.3.0c Release Notes (AA-RWEYG-TE, November 2007)
Table Of Contents
- HP StorageWorks Fabric OS 5.3.0crelease notes
- Version
- Effective date
- Description
- Update recommendations
- Supersedes
- Supported product models
- Support for embedded switch models
- Unsupported product models
- Devices supported
- Operating systems
- New features in Fabric OS 5.3.0
- New Web Tools features in Fabric OS 5.3.0
- Prerequisites
- Firmware upgrade instructions
- Important notes
- Additional Fabric OS 5.3.0 enhancements
- Additional Web Tools 5.3.0 enhancements
- Fabric OS 5.3.0 fixes
- Fabric OS 5.3.0a fixes
- Fabric OS 5.3.0b fixes
- Fabric OS 5.3.0c fixes
Web Tools incorrectly returns “Directory change failed” error
message rather than “file path provided is not valid” error message
when config upload fails due to invalid file path.
Fixed per Fabric OS 5.3.0
Modifying port speed and trunking on FC4-48 ports from Web Tools,
followed by HA
failover, and then tr ying to re-launch, Port Admin
window on those same ports fails to reload Web Tools window.
Fixed per Fabric OS 5.3.0
F_Port route cleanup doesn’t happen correctly when NPIV is used on
switch in Access Gateway mode.
Fixed per Fabric OS 5.3.0
EZSwitch Setup device display is overlapped in Display Connection
window when window size not maximized.
Fixed per Fabric OS 5.3.0
Portstatsclear help page description of behavior on 2Gb and
4Gb platfor
ms is ambiguous.
Fixed per Fa
bric OS 5.3.0
FR4-18i tracedump files contain many BP error messages and one
empty file, potentially leading to incomplete support files.
Fixed per Fabric OS 5.3.0
During stress testing when rebooting all core switches in a loop,
E-ports may get stuck in “Mod_Val” m ode.
Fixed per Fabric OS 5.3.0
Error messages are generated when applying iSCSI easycreate
operatio
nfromWebToolsonunreachableFCTargets. Noerror
messages if LUN information is not retrievable from an FC Target.
Errors are only displayed when applying the operation.
Fixed per Fabric OS 5.3.0
If Dynamic Load Sharing (DLS) or In-Order Delivery is disabled, it
can’t be enabled from Web Tools. However, it can be set/reset via
CLI.
Fixed per Fabric OS 5.3.0
Web Tools event filtering uses a time range of 0-11 rather than 1 -12.
In Web Tools Fabric Events and Events window, on invoking filter
button and filtering based on “from” time or “to” time, on providing a
time greater than 12 (e.g. 12:30 PM) will result in an error stating
that time should be in range of 0-11.
Fixed per Fabric OS 5.3.0
Additional Port Info column in FC Ports tab in Web Tools shows
"None (FMS Mode)" instead of "Disabled (FMS Mode)."
Fixed per Fabric OS 5.3.0
FR4-18i blades rebooted during firmware commit process per
firmwaredownloadstatus output. Process does recover .
Fixed per Fabric OS 5.3.0
With EZSwitchSetup, fixed zone can’t be configured with all
portsdesignatedasstorageorhosts. Thisiscorrectbehavior,
but the message displayed doesn’t describe how to correct the
misconfiguration should the user attempt to configure in that manner.
Fixed per Fabric OS 5.3.0
Error messages occur during IPsec FCIP IO. Fixed per Fabric OS 5.3.0
Incorrect information returned during Request Node Identification
Data (RNID) registration.
Fixed per Fabric OS 5.3.0
User sees wrong port type after port swap on issuing fwsamshow
from CLI, due to port type getting swapped in the SAM Report.
Fixed per Fabric OS 5.3.0
Due
to current handling of invalid zone type during zone enforcement
after failover, Name Server daemon (nsd) panic results in CP fault
after firmwaredownload.
Fi
xed per Fabric OS 5.3.0
Unable to view policy details in the absence of IPSEC license from
“ShowIPSecuritypolicies”.
Fixed per Fabric OS 5.3.0
After changing an expired password and selecting another Admin
Domain during the same session, the password expiration message
and p assword prompt are displayed again. Currently have to exit
session and re-login after changing an expired password to avoid
this issue.
Fixed per Fabric OS 5.3.0
20