When FRU in a 4/256 Director is inserted/removed a
fruHistoryTrap should be generated, but is not.
Fixed in Fabric OS 5.3.0c. Note
that fruStatusChangeTrap
will not be generated with FRU
insert/remove.
After upgrading switches to FOS 5.3.0, the Web Tools GUI bar
showing the "I
nitializing Switch Details" will get stuck at 93% if
the client’s
regional and language settings are set to some non-US
languages su
ch as Dutch, Russian, and Greek. English, French,
German, Italian, Spanish, Por tuguese, Simplified Chinese, Traditional
Chinese, Ja
panese and Korean work fine.
Fixed per Fabric OS 5.3.0c.
A PLOGI received by 400 MP Router or FR4-18i prior to address
tra nslation table being programmed may not get the correct domain
name offset while operating in the open fabric mode, leading to
inability to boot over FCR connection for host that doesn’t retr y PLOGI.
Fixed per Fabric OS 5.3.0c.
Web Tools shows Ethernet speed at 0, even though it’s operating at
correct speed, due to underlying MAPS returning speed type rather
than proper speed.
Fixed per Fabric OS 5.3.0c.