EZSwitchSetup Limitations
This section provides the following information:
General Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . 43
General Limitations
Table 1 lists general EZSwitchSetup limitations, which apply to all browsers and switch platforms.
TABLE 1 EZSwitchSetup Switch Manager Limitations
Problem Area Details
HTTP timeout Very often, you might see the following message when you try to get data from a switch
or to send a request to the switch:
Failed to get switch response. Please verify the status
of your last operation and try again if necessary.
This indicates that an HTTP request did not get a response. The request was sent to the
switch, but the connection was down, probably caused by a temporary loss of the Web
server on the switch. Due to the nature of an HTTP connection, Switch Manager will
report this error after a 90-second default timeout.
In this case, verify the status of your last request, using telnet to check related status,
or click the Refresh button in the Switch Manager to retrieve related data. If your
request did not get through to the switch, resubmit it. Executing a refresh from Switch
Manager retrieves a copy of switch data at that moment; the data you entered can be
lost if it had not already committed to the switch.