Fabric OS Troubleshooting and Diagnostics Guide v6.4.0 (53-1001769-01, June 2010)

Fabric OS Troubleshooting and Diagnostics Guide 85
53-1001769-01
Chapter
10
Working With Diagnostic Features
In this chapter
About Fabric OS diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Power-on self test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Switch status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
SpinFab and portTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Port information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Equipment status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
System message log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Port log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Syslogd configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Automatic trace dump transfers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
About Fabric OS diagnostics
The purpose of the diagnostic subsystem is to evaluate the integrity of the system hardware.
Diagnostics are invoked in the one of the following ways:
Automatically during the power-on self test (POST).
Automatically on an individual blade whenever it is installed into a director chassis.
Manually using Fabric OS CLI commands.
The error messages generated during these test activities are sent to the serial console and system
message logs, whose output formats may differ slightly.
Use the diagHelp command to receive a list of all available diagnostic commands.
See the Fabric OS Command Reference for a complete description of each command.
Diagnostic information
On the switch you can enter the supportShow command to dump important diagnostic and status
information to the session screen, where you can review it or capture its data. If you are using a
Telnet client, you may have to set up the client to capture the data prior to opening the session
Most information can be captured using the supportSave command and FTP’d off the switch, but
when you are collecting information from specialized commands, such as supportShow, this
information has to be captured using a Telnet client.