HP StorageWorks Fabric OS 5.2.0b Release Notes (AA-RWEYB-TE, February 2007)

User is not informe
d with the IPSec mismatch RAS event when configuring
a tunnel with IPSec
mismatch on either ends.
Fabric Merge
Do not try to merge fabrics with conflicting domain IDs over a VE_Port.
Before merging two fabrics over FC-IP with VE _Ports at each end, it is
recommended that all domain ID and zoning conflicts are resolved.
Scalability
Support for Default Zoning policies has been added to Fabric OS 5.1.0.
Typically, when you issue the cfgDisable command in a large fabric
with thousands of devices, the name server indicates to all hosts that they
can communicate with each other. To en sure that all devices in a fabric
do not see each other during a cfgDisable operation, you can activate
a Default Zone with policy set to no access”. If Default zoning policies
are enabled, all cfgEnable/disable commands and zoning changes
must be run from a switch in the fabric running Fabric OS 5.1.0/5.2.0a.
In large fabrics with more than 1,000 ports, it is recommended that the
MS Platform Database is disabled. It is also required that the Platform DB
be disabled before downgrading to previous versions of Fabric OS. This
canbedoneusingthemsPLMgmtDeactivate command.
FRU insertion
The FW_FRU_INSERTED message is displayed twice when a power supply
FRU is
inserted and powered on. There is no functional impact.
System boot Not all Fabric OS services are available when the prompt becomes available
during boot up. Wait for all the services to come up before using the switch
or performing zoning actions.
Performance Monitoring If the user tries to save more than 512 monitors using the perfCfgSave
command, some of the monitors may be lost.
Man
agement Proxy switches
If you are using a Fabric OS 4.x switch as an API or SMI-S proxy to manage
a 5.1.0 switch, you must be running Fabric OS 4 .4.0d.
FCIP
Frame drops observed on FCIP slow links:
—The frame d rops occur when the FCIP tunnel bandwidth is set to 10 Base-T
(10Mbps), E1 (1.048Mbps), or T1 (1.544Mbps).
—With E1 or T1, frames are dropped even without an impaired link.
—With 10 Base-T, frame drops may be observed when a low impairment
is put to the link.
portperfshow indicated incorrect (smaller) bidirectional throughput on
the FCIP tunnel when Fast write/Tape Pipelining is enabled.
Fastwrite/Tape Pipelining did not inform user when it failed due to
multiple equal paths configured on 2 GbE ports.
Backup jobs initiated from the Symantec BackupExec application slowed
noticeably after adding significant IO traffic from regular hosts and
targets to the FCIP tunnel. Port-based routing policy must be used for
Tape devices.
18