HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

Important Notes
19Fabric OS 3.1.3a Release Notes
Other Notes
Table 4 list important information for Fabric OS v3.1.3a.
Invalid CRC
count
Monitors
number of
CRC errors
Unit
Time Base
Low
High
Buffer
Error(s)
Minute
1
5
0
Changed
Exceeded
Below
Above
In-between
0
0
1
1
0
Informative
Informative
Normal
Faulty
Informative
State
changes
Monitors
state
changes
Unit
Time Base
Low
High
Buffer
Error(s)
Minute
1
15
0
Changed
Exceeded
Below
Above
In-between
0
0
1
1
0
Informative
Informative
Normal
Faulty
Informative
Table 3: Fabric Watch Default Settings (Continued)
Class
Class Area
name
Description Default Settings
Threshold Setting Alarm Setting
Threshold
State
Table 4: Fabric OS Area Information
Fabric OS Area Description
Fabric configuration During fabric configuration, the countdown message that used to
appear on the console is removed starting with Fabric OS v2.6.2,
v3.1.2, and v4.2.x. The fabric reconfiguration message is now captured
in the error log. For details, refer to the diagnostic messages in the HP
StorageWorks Diagnostic and System Error Messages 3.1.x/4.1.x
Reference Guide.
Fabric Watch: e-mail
alert error message
If an event occurs while Fabric Watch e-mail alerts are being enabled,
the message ErrLog: Error Level=3 [(null)] is captured
to the system error log. This message is from SMTP and can be
ignored.
FARP requests Fabric OS v2.x and v3.x do not support FARP requests, only ARP
requests. When using IP over Fibre Channel, confirm that all host
HBAs support ARP requests and issue ARP requests.