HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

CLI Command Updates and Changes
26 Fabric OS 3.1.3a Release Notes
Examples
The following example shows the pathInfo command invoked with all
operands on the command line:
source route
Specifies a sequence of switches or ports that the
pathInfo frame should traverse. Note that if an
output port (or area) to the next hop is specified,
then the user will not be prompted for the domain
of the next switch; that is determined by the port
(or area) specified. Default: no.
strict source rte Specifies that the source route must be followed
strictly as indicated, skipping possible
intermediate switches. When using this option, the
source route must be specified using domain
numbers (rather than the output port).
Timeout The maximum time allowed to wait for the
response. Default: 10 seconds.
web226:root> pathInfo 91
Target port is Embedded
Hop In Port Domain ID (Name) Out Port BW Cost
-------------------------------------------------------------
0 E 9 (web226) 2 1G 1000
1 3 10 (web229) 8 1G 1000
2 8 8 (web228) 9 1G 1000
3 6 91 (web225) E - -