HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
34 Fabric OS 3.1.3a Release Notes
New Diagnostic and System Error Messages
This section describes new system error messages.
Message
Critical DIAG-BADINT, 1
Probable Cause
The ASIC central memory SRAMs did not complete the BISR within the timeout
period. This usually indicates DIAG-BADINT.
Severity
Critical
Message
Critical DIAG-BUS_TIMEOUT, 1
Probable Cause
ASIC internal logic failed. This usually indicates an ASIC failure. This message is
generated by the filtertest command, if problems are found.
Recommended Action
Replace the motherboard FRU for the SAN Switch 2/16.
Replace the entire switch or the SAN Switch 2/8.
Severity
Critical
DIAG-BADINT
DIAG-BUS_TIMEOUT