HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
35Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CAMFLTR, 1
Probable Cause
Port received an unexpected interrupt. This usually indicates an ASIC failure. This
message is generated by the centralmemorytest or the cmitest
command, if problems are found.
Recommended Action
Replace the motherboard FRU for the SAN Switch 2/16.
Replace the entire switch or the SAN Switch 2/8.
Severity
Critical
Message
Critical DIAG-CAMINIT, 1
Probable Cause
Port failed to initialize due to one of the following reasons:
Switch not disabled
Diagnostic queue absent
Malloc failed
Chip is not present
Port is not in loopback mode
Port is not active
Software operational setup error or motherboard failure
DIAG-CAMFLTR
DIAG-CAMINIT