HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
36 Fabric OS 3.1.3a Release Notes
This can be caused by a faulty cable or deteriorated SFP. It can also indicate
deeper problems in the motherboard or ASIC. This message is generated by the
camtest command.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if
necessary.
If the problem persists:
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CAMSID, 1
Probable Cause
ASIC failed SID NO translation test. This usually indicates an ASIC failure. This
message is generated by the camtest command.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-CAMSID