HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
39Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CMERRPTN, 1
Probable Cause
Error detected at the wrong port. This usually indicates an ASIC failure. This
message is generated by the centralmemorytest command, if problems are
found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CMERRTYPE, 1
Probable Cause
A port received the wrong CMEM error type. This usually indicates an ASIC
failure. This message is generated by the centralmemorytest command, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-CMERRPTN
DIAG-CMERRTYPE