HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
40 Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CMICKSUM, 1
Probable Cause
CMI message received failed. This usually indicates an ASIC or motherboard
failure. This message is generated by the cmitest command, if problems are
found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CMIDATA, 1
Probable Cause
CMI data received did not match data transmitted. This usually indicates an ASIC
or motherboard failure. This message is generated by the cmitest command, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-CMICKSUM
DIAG-CMIDATA