HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
42 Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CMISA1, 1
Probable Cause
An attempt to send a CMI message from ASIC to ASIC failed. This usually
indicates an ASIC failure. This message is generated by the cmitest command,
if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CMNOBUF, 1
Probable Cause
Port could not get any buffers. This usually indicates an ASIC failure. This
message is generated by the centralmemorytest command, if problems are
found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical