HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
51Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-INTNOTCLR, 1
Probable Cause
The interrupt bit could not be cleared. This usually indicates an ASIC failure. This
message is generated by the centralmemorytest command, if problems are
found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-LCMEM, 1
Probable Cause
Data read from the central memory location did not match data previously written
into the same location. This usually indicates an ASIC failure. This message is
generated by the centralmemorytest and cmemretentiontest
commands, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-INTNOTCLR
DIAG-LCMEM