HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
52 Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-LCMEMTX, 1
Probable Cause
Central memory transmit path failure: ASIC 1 failed to read ASIC 2 using the
transmit path. This usually indicates a motherboard failure. This message is
generated by the centralmemorytest command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-LCMRS, 1
Probable Cause
Central memory read short: number of bytes requested not received. This usually
indicates an ASIC problem. This message is generated by the
centralmemorytest and the cmemretentiontest commands, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-LCMEMTX
DIAG-LCMRS