HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
53Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-LCMTO, 1
Probable Cause
Central memory timeout: data transfer initiated did not complete within the
timeout period. This usually indicates an ASIC failure. This message is generated
by the centralmemorytest and the cmemretentiontest commands, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-MEMNULL, 1
Probable Cause
The ASIC failed to allocate memory. This usually indicates a motherboard failure.
This message is generated by the ramtest command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-LCMTO
DIAG-MEMNULL