HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
54 Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-MEMORY, 1
Probable Cause
Data read from RAM location did not match previously written data into the same
location. This usually indicates a CPU RAM failure. This message is generated by
the ramtest command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-MEMSZ, 1
Probable Cause
Memory size to be tested is less than or equal to zero. This usually indicates a
motherboard failure. This message is generated by the ramtest command, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-MEMORY
DIAG-MEMSZ