HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQYC-TE, September 2004)

New Diagnostic and System Error Messages
59Fabric OS 3.1.3a Release Notes
Critical DIAG-REGERR, 1
Probable Cause
Data read from an ASIC register or ASIC SRAM did not match data previously
written into the same location. This usually indicates an ASIC failure. This
message is generated by the portregtest or the sramretentiontest
commands, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-REGERR_UNRST, 1
Probable Cause
Port failed to unreset. This usually indicates an ASIC failure. This message is
generated by the portregtest or the sramretentiontest commands, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-REGERR
DIAG-REGERR_UNRST